Stablo-AP ionizer for static removal. AC corona discharge method; range: approx 400mm; static elimination time: 1s (typical value) (+/- 1000V to +/- 100V). DC24V, 1.0A.

logo

ERP
SZ-321-73700-03
Regular Price CA$1,279.00 Special Price CA$1,151.10
EA

The Largest 100% Canadian Owned and Operated Lab Equipment Distributor and Service Provider.

Free Technical Support

In-depth and personal over-the-phone support at no cost.

Quality Parts & Accessories

Mandel uses manufacturer-specified parts for all repairs and maintenance.

Static Electricity Removal by Ion Irradiation

With the high-frequency AC corona discharge method, Shimadzu’s STABLO-AP ionizer provides a stable ion balance and excellent static removal performance on samples and containers. Precision weighing work becomes remarkably efficient. Electrodes are safely housed inside the unit.

diagram

AC Method Produces Excellent Ion Balance

AC method: AC voltage is applied on the discharge needle and a well-balanced mixture of positive/negative ions is emitted in rapid alternation from one electrode.

DC method: DC voltage is applied to a couple of electrodes. One is positive and the other is negative. Each electrode emits ions of one polarity only. An effective static removal angle is limited if the two electrodes are distanced. As electrodes deteriorate, initial ion balance is lost.


Application

On Stand
While being neutralized, charge-prone samples can be injected into a container without being scattered. You can also easily neutralize spatulas and sample bottles in the midst of the work flow. Samples can be neutralized before weighing measurements.

product

Hand Held
You can neutralize sample static electricity during weighing measurements. Move the unit freely to any position where static electricity is a concern and then neutralize it.


Use an Ionizer for Stable, Accurate Measurements!

The AP series analytical balances (AP-W and AP-X series) are equipped with the space for incorporating the ionizer, and with an interface allowing for operation using the main unit’s keyboard. As seen in the video, simply pressing one button on the main unit’s panel eliminates static electricity. This makes stable measurements possible.


The Anti-Static STABLO AP Can Also Be Used as a Stand-Alone Device

In addition to being incorporated within AP series analytical balances (AP-W and AP-X series), the STABLO AP ionizer can also function as a stand-alone device.
When being used as a stand-alone unit, the device can be used in two ways. It can either be used in a fixed position using the stand included as standard, or it can be used as a handheld device, allowing it to be moved freely to any desired position. This allows the unit to be used for a variety of purposes other than balance measurements, such as for eliminating static electricity from samples or containers.

Static removal method

AC corona discharge

Static removal range

Approx. 50 to 400 mm from discharge electrode

Static removal time

1 second (without wind)

Ozone Concentration

0.06 ppm or less (at 150 mm from the outlet)

Eliminate Static Electricity, the Measurement Disruptor!

Not only is static electricity a source of discomfort for people, it also has a harmful effect on measurements. 
The following video shows the influence on measurements that samples carrying an electrostatic charge can have, and how an ionizer (anti-static device) can be used to alleviate the problem.


Measurement of Samples Carrying an Electrostatic Charge

When a sample carrying an electrostatic charge is put in place, the measured value becomes unstable, and measurement cannot be performed.