Model S-3000AB, Standard LN2 Container Including 2301 Autofill-Monitor System with Gas By-Pass and LN2 Hose; Features: Round space saving design, rust-free stainless steel vessel, castor mounted for easy mobility, advanced woven lid gasket design, counter

logo

ERP
CBS-33305
Request a quote

The Largest 100% Canadian Owned and Operated Lab Equipment Distributor and Service Provider.

Free Technical Support

In-depth and personal over-the-phone support at no cost.

Quality Parts & Accessories

Mandel uses manufacturer-specified parts for all repairs and maintenance.

Custom BioGenic Systems S3000-AB Liquid Nitrogen Freezers offer conventional immersion liquid nitrogen storage. The wide lid opening provides easy, unrestricted access to samples and won't affect the temperature inside the freezer. All S Series freezers use CBS's time-tested and reliable 2301 controller with a dual autofill and many additional features.

  • Round space-saving design
  • Rust-free stainless steel vessel
  • Castor-mounted for easy mobility
  • Advanced woven lid gasket design
  • Counterbalanced lockable lid
  • Annular fill and sensor tubes

Accommodates:

  • Aluminum square racks
  • Stainless steel square racks
  • Vertical racks
  • Mini racks
  • Canister and frame systems
  • Vials
  • Boxes
  • Canisters / cassettes
  • Platform dividers
  • Pie Racks
  • Pie Boxes

Performance

LN2 Capacity (Litres): 345

Exterior Dimensions: Inches (mm)

Width: 34 (863)
Depth: 43 (1,092)
Height: 42 (1,066)

Interior Dimensions: Inches (mm)

Usable Height: 29 (736)
Usable Diameter: 31 (787)

Maximum Storage Capacities

Vials (2mL): 22,100
Blood Bags (50mL): 1,120


CBS's 2301 controller is time tested, reliable and designed to keep your sample storage safe and secure.

New 16 Port Connector:

  • 0-5 volt outputs provide temperature & level data for connection to existing alarm/monitor system
  • 4-20 mA outputs provide temperature & level data for connection to exisitng alarm/monitor system
  • Sequential and One-Fill-All-Fill input and output connection for filling systems

New two level temprature display option:

  • Temp. A displays temperature at the lid, approximately 11"(27.94cm)
  • Temp. B displays temperature inside the storage space, approximately 20"(50.80cm)

Additonal Features:

  • Records 12 alarms & events such as fill start, fill stop, etc. with dated time stamp, printed or displayed
  • Ethernet and auxiliary RS485 for future expansion
  • Dedicated 24Vdc signal output to activate a third 24Vdc valve to control the LN2 supply
  • Global Remote Alarm-Dry contact that switches during any alarm condition
  • Date Log- Print or display Temp. A, Temp. B and level with date and time stamp