GCMS-QP2050

GCMS-QP2050

The GCMS-QP2050 with the new DuraEase ion source maximizes uptime and sensitivity while requiring minimum maintenance, which can be completed in just a few minutes and a few simple steps.

New cost-effective ion source design allows customers to replace DuraEase source when needed, maintaining pristine condition. The built-in pre-rod allows only the ions to efficiently pass through, limiting contamination of the quadrupole.

logo

Advantages of the Single Quad GCMS-QP2050

Detector | The new model is equipped with both the latest noise suppression technology and high amplification performance, and can accurately assess even trace ions
Quadrupole Rods | By significantly improving mass separation performance and ion transmittance, the system achieves the industry's highest level of scan speed (30,000 u/sec)
Interface | The new interface has been optimized to ensure a uniform temperature distribution
DuraEase Ion Source | DuraEase technology enables this next-generation ion source to achieve the industry's highest level of sensitivity, durability, and ease of maintenance.
Long-life Filament | Highly durable new filament has an operating life about five times longer than usual
Equipment Size | 20% slimmer than the GCMS-QP2010SE


Minimum Maintenance, Maximum Progress

A contamination-resistant ion optical system in the GCMS-QP2050 keeps the frequency of maintenance to a minimum while also enabling highly reliable measurements to be performed for an extended period.

DuraEase Ion Source

DuraEase Ion Source

The structure of the next-generation DuraEase ion source is inert and achieves a uniform temperature distribution, resulting in high sensitivity and exceptional durability.

Quadrupole Rods with Pre-Rod

Quadrupole Rods with Pre-Rod

The built-in pre-rod allows only the ions to efficiently pass through, limiting contamination of the quadrupole. In addition, because heating to prevent contamination is not required, it is maintenance-free.

Long-Life Filament with 1/5th the Conventional Replacement Frequency

The newly developed long-life filament has an operating life at least five times longer than conventional filaments. There are no concerns about re-analysis or downtime due to sudden filament burnout.

Long-Life Filament with 1/5th the Conventional Replacement Frequency

High Durability in Consecutive Analyses

The GCMS-QP2050, which boasts incomparable robustness, achieves extremely stable measurements, even during consecutive analyses of VOCs in water, by eliminating the effects of elution of the column bleed to the utmost limit.

500 consecutive analyzes of VOCs in water using the headspace method

500 consecutive analyzes of VOCs in water using the headspace method


Simple Operation, Confident Results

Easy Maintenance

Ion Source Maintenance Takes Just One Minute

The DuraEase ion source introduces a thorough redesign of the traditional ion source structure, aiming to enhance maintenance convenience significantly. The ion source is disposable and no cleaning is required, so maintenance is finished in just one minute.

Easy GCMS Maintenance
One-Touch GC Inlet Maintenance

 

One-Touch GC Inlet Maintenance

The instrument comes standard with a ClickTek™ nut, allowing easy attachment or detachment of the GC injection port by manually manipulating a lever, without the need for tools.

 

Easy Startup and Shutdown from the Touch Panel

The vacuum system can be turned ON/OFF and Easy sTop* can be performed from the GC touch panel. Operations from a personal computer are not required, so maintenance of the GC injection port, column, and ion source can proceed with ease.

* This function guides the user through the replacement of the GC injection port septum and glass insert without turning OFF the vacuum system.

Examination of the analytical conditions is indispensable for acquiring better data. The GCMS-QP2050 reduces the burden of examining these conditions, allowing even novice users to acquire data on par with an experienced operator.

Easily Analyze a Wide Range of GCMS Applications

With the completely new ion source and detector, the system is more than capable of detecting even trace compounds.

Easily Analyze a Wide Range of Applications

The new interface, which minimizes the production of cold spots, enables the acquisition of favorable peak shapes and sensitivity, even for compounds prone to adsorption.

New GCMS Interface

 

GCMS Example of the Analysis of Tetracontane

Example of the Analysis of Tetracontane

Ultra Fast Scanning Technology Supports Accurate Measurements

Advances to Shimadzu's impressive technology resulted in the industry's highest scan speed of 30,000 u/sec. As a result, sensitivity on par with SIM analysis can be obtained even with FASST*1. In addition, Advanced Scanning Speed Protocol (ASSP™*2) minimizes sensitivity loss, even when the Scan measurement range is widened, enabling accurate qualitative analysis.

*1 Fast Automated Scan/SIM Type: In this measurement mode, switching rapidly between Scan mode and SIM mode enables high-sensitivity SIM analysis and Scan analysis for component confirmation to be performed simultaneously in a single analysis.
*2 By automatically optimizing the rod bias voltage during high-speed scans, this control technology minimizes sensitivity drops during high-speed scans.

Mass spectra of ChlornitrofenMass spectra of Chlornitrofen
Mass spectra of chlornitrofen

Mass spectra of Chlornitrofen

LabSolutions GCMS

 


LabSolutions™ GCMS

Maximize Efficiency of the Entire Workflow

The LabSolutions™ GCMS software, featuring Analytical Intelligence and Shimadzu's cutting-edge user support technology, empowers novice users to effortlessly obtain data across diverse applications, akin to experienced operators. Covering everything from preparation to measurement and data analysis, LabSolutions™ GCMS software enhances workflow efficiency and offers laboratory flexibility through remote system access.

Automatic Creation of GCMS Analysis Methods

Smart SIM™+ automatically creates the optimal analysis method. As a result, high-sensitivity and high-accuracy analysis is possible, even in multicomponent quantitative analysis.


Automatic Creation of GCMS Analysis Methods

Database Optimized for Each Field

The compounds that need to be measured for each application are registered in Smart Database™. The optimized analytical conditions enable favorable measurement results to be obtained regardless of the operator's experience level.

Database Optimized for Each Field

Time Management for the Measurement Workflow ANALYTICAL INTELLIGENCE

Time Management for the Measurement Workflow

You can monitor the current status of each instrument in the laboratory and check the estimated completion time for consecutive analyses in real time. Additionally, the remaining time until the startup and shutdown of each instrument is displayed, contributing to improved laboratory productivity and heightened efficiency.

Automatic Peak Integration by Artificial Intelligence ANALYTICAL INTELLIGENCE

Automatic Peak Integration by Artificial Intelligence

 

Peakintelligence™ for GCMS, which is equipped with AI peak integration algorithms, significantly shortens the time required for peak integration and provides results comparable to those obtained by an experienced operator.

 

Improved Throughput for Multisample Data Analysis

Improved Throughput for Multisample Data Analysis

The LabSolutions™ Insight multisample quantitative support software significantly reduces the time needed to analyze multisample data. Using flag, filter, and peak comparison functions, the multisample data can be narrowed down to the components that should be the focus.

Maintenance Navigation ANALYTICAL INTELLIGENCE

The Easy sTop function enables safe maintenance of the sample injection port without stopping the vacuum. The standby time until maintenance can be performed is shown in real time.

Maintenance Navigation

One Instrument, Infinite Possibilities

Conquering Helium Shortages

Minimizing the Usage of Helium Gas

To address helium shortage challenges, the GCMS-QP2050 is alternative carrier gas ready out-of-the-box. All stainless-steel internal plumbing allows for immediate hydrogen connection. The system also includes a carrier gas saver function, and can be equipped with an optional carrier gas selector module and a Hydrogen sensor, ensuring lab safety.

Minimizing the Usage of Helium Gas
Minimizing the Usage of Precious Helium Gas

Reliable Operation with Alternative Carrier Gases

The carrier gas can be cost-effectively supplied by using hydrogen and nitrogen, readily available and more affordable alternatives. The GCMS-QP2050, equipped with a high-performance flow controller and a design minimizing the carrier gas impact, can reliably conduct stable measurements using either gas without requiring modifications to the instrument configuration.

Reliable Operation with Alternative Carrier Gases

Hydrogen Carrier Gas

Hydrogen Carrier Gas

Hydrogen is the first choice as an alternative carrier gas from the perspective of sensitivity and separation. By installing the optional hydrogen sensor, if a leak occurs, the system automatically switches to safe standby mode, adding a level of comfort to anyone concerned about using hydrogen.

Nitrogen Carrier Gas

The GCMS-QP2050 demonstrates its true value when nitrogen is used as the carrier gas. In constant linear velocity mode, the system achieves separation on par with helium even when using nitrogen carrier gas, which has a narrow range of optimal linear velocities.

 

A Flexible Fit to Laboratories

Remote System Access

The system can be operated from a personal computer or tablet on the network via a LAN connection. This allows users to monitor analysis progress and check instrument status even when they are not in the laboratory.

System can be Accessed Remotely

Compact Design Fits Anywhere

The GCMS-QP2050 saves on space. Thanks to remote access, there is no need to install a personal computer beside the instrument. This enables a flexible layout in the laboratory.

Compact Design for Single Quad GCMS

 

Energy Saving GCMS

Enregy Saving
The GCMS-QP2050 is equipped with ecology mode, which can reduce power consumption. It is also recognized as Eco-Products Plus, Shimadzu’s proprietary recognition of environmentally friendly products. In addition to limiting analysis running costs, CO2 emissions are limited, thereby contributing to a carbon-free society.