ICPMS-2030

ICPMS-2030

Featuring unique analysis assistant functions and incorporating proprietary cost-reducing capabilities, the ICPMS-2030 provides efficient, sensitive trace element analysis for applications in multiple industries. These include environmental testing, food and agriculture studies, cannabis testing, and pharmaceutical work for analysis of toxic elements according to USP regulations. Simplify your ICP-MS analysis, and obtain reliable trace-level results with confidence.

logo

Fast, Easy Method Development

The system’s Development Assistant automatically selects the optimal mass and internal standard for the target elements, and suggests concentration ranges for calibration curves, allowing any ICP-MS user to develop reliable methods with ease.

Conventional ICP-MS Method Development Process (when analyzing a sample for the first time) versus Creating Analytical Method Using Development Assistant

 

Automated Post-run Diagnostics

The Diagnosis Assistant identifies the presence or absence of mass interference based on qualitative analysis to quickly generate reliable ICP-MS results.

Checking ICP-MS Data Conventionally versus Checking Data Using Diagnosis Assistant

 

Outstanding Sensitivity

The optimized collision cell achieves superior ICP-MS sensitivity through efficient molecular ion removal and high elemental ion transmission using only helium gas.

 

Reduced Running Costs

The ICPMS-2030 inductively coupled plasma mass spectrometer significantly reduces operating costs utilizing Shimadzu’s proprietary technology. This includes:

  • Mini-Torch system, which effectively reduces the amount of argon gas needed to generate plasma (consumes 2/3 the argon gas as conventional plasma torches)
  • ECO mode, which minimizes the flow rate and power consumption during standby
  • Compatibility with 99.95% purity argon gas, instead of the more expensive 99.999% argon gas generally used

ICPMS-2030 Eco Mode versus Conventional ICP-MS

 

Simultaneous Analysis of Major and Trace-level Components

Nine orders of magnitude dynamic range with a secondary electron multiplier, enabling ICP-MS analysis of major and trace-level components in the same sample.

 

On-Line Inter-Element Correction (IEC)

Shimadzu's proprietary On-Line IEC corrects for spectral interference that could not be eliminated with the collision cell. There's no need for complicated assessments of ICP-MS conditions, as with reaction cell technology.

 

Minimized Contamination

Located behind the collision cell, the focusing lens improves ion transmission efficiency and eliminates photoelectric effects, optimizing the ICPMS-2030’s compatibility with laser ablation systems.

 

Easy-to-Maintain Interface and Plasma Torch

Allows all parts to be removed and installed without the need for tools, resulting in greater uptime.

Plasma Stand with Wide Opening Allowing Easy Access