AUTOPOL V Automatic Polarimeter

AUTOPOL V Automatic Polarimeter

The AUTOPOL® V Automatic Polarimeter is designed for today’s FDA regulated analytical laboratories. Whether you are a Pharmaceutical, Nutraceutical or University Lab, the AUTOPOL® V has the standard measurement and compliance features you must have, including:

  • TempTrol™ – Electronic cooling and heating from 15°-35°C
  • 21CFR Part 11 Compliance: electronic signature and secure local data storage
  • Six Standard Wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm, 633nm
  • Standard Accessories: TempTrol™ NIST Traceable Quartz Standard, TempTrol™ 100mm Polarimeter Cell, TempTrol™ Temperature Validation Cell and Built-In Sample Measurement Probe.
  • 3-year domestic warranty and 20-year support guarantee

TempTrol™ Electronic Temperature Control System


The TempTrol™ System allows push-button temperature control of your TempTrol™ 100mm cell, 200mm cell or Quartz Control Plate. Set the temperature, push “measure” and walk away. The AUTOPOL® V Fully Automatic Polarimeter will heat or cool to a predefined temperature and then provide you with the result, all in one easy step.

The TempTrol™ System will accurately control your sample temperature to within ±0.2°C.


The AUTOPOL® V Automatic Polarimeter Offers Acid Resistance and Traceable Quartz Plates

  • 6m HCl acid resistance: Silco Steel coating on the polarimeter chamber temperature transfer surface and a Hastelloy measurement cell with NIST certificate certifying optical path length.
  • To meet the FDA’s latest position on measurement bracketing, the Autopol® V Plus comes with a NIST traceable quartz plate with three rotations: +0.998° Arc, +10.998° Arc, -10.000° Arc. Each rotation has a NIST certificate.

Automatic Polarimeter with Six Wavelengths and Only One Light Source

The AUTOPOL® V Automatic Polarimeter comes standard with six wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm, 633nm. Wavelength selection is completely automatic and is accomplished by the push of a button. There are no lamps or filters to manually remove or insert.

The tungsten-halogen lamp employed in the AUTOPOL® V Polarimeter is a compact, reliable, low-cost, high intensity light source that allows any desired wavelength in the visible spectrum to be selected by means of a narrow band multilayer interference filter. The AUTOPOL® standard 10nm bandwidth is specified to permit high energy throughput and sensitivity for sample transmittances of only 0.01 % (O. D. = 4), while minimizing the effects of sample ORD and colour.


Standard Accessories, Validation and Calibration


The AUTOPOL® V Polarimeter comes standard with the accessories, validation tools and automatic calibration functions necessary to ensure that the temperature control, temperature measurement and optical measurement processes are working correctly and reproducibly. All functions are accessed simply and conveniently through the AUTOPOL® V liquid sealed touchscreen.


Autopol® V Polarimeter Standard accessories include:

  • TempTrol™ NIST Traceable Quartz Standard
  • TempTrol™ 100mm Polarimeter Cell
  • TempTrol™ Temperature Validation Cell
  • Built-In Sample Measurement Probe
  • 1 Front Facing USB and 2 Rear Facing USB – Allows quick and easy connection to a mouse, keyboard, printer, bar code scanner, or memory stick
  • Serial Port
  • Ethernet Port

The AUTOPOL® V also accepts all Rudolph Standard Cells and Quartz Plates.


Laboratory Network and Printer Communications Simplified

  • Ethernet Port for Network Cable Connection
  • Internet access allowing connection to Rudolph’s service department for remote testing and diagnostics
  • Connect to any Windows® based printer via USB or direct to the server via Windows® Print Library
  • Save measurement data direct to your Network/Server/USB Drive

Automatic, Electronic Polarimeter Temperature Control System using TempTrol™

The USP <781> require optical rotation measurements at 25°C ± .5°C (unless another temperature is specified). The European Pharmacopoeia requires optical rotation measurements made at 20°C ± .5°C (unless another temperature is specified).

Whatever your temperature control needs are, the AUTOPOL® V’s exclusive TempTrol™ System (Patent No. 6,717,665) makes your measurement in a few minutes without a waterbath or any type of water circulation.

The TempTrol™ System allows push-button temperature control of your 100mm cell, 200mm cell, or Quartz Plate. Set the temperature, push “measure” and walk away. The AUTOPOL V will heat or cool to a predefined temperature and then provide you with the result all in one easy step.


Patented TempTrol™ Technology Eliminates the Need for a Water Bath. Here is How the TempTrol System Works:


TempTrol™ heating and cooling transfer surface in the polarimeter sample chamber

TempTrol™ cell is placed in the sample chamber with mating heating & cooling transfer surface, manufactured with acid resistance materials: Hastelloy™ and Peek™.
Polarimeter-Sample-Chamber-3
Temperature is selected via touch screen. Temperature selection of 20°C shown left.

Place the TempTrol™ cell in your TempTrol™ equipped Autopol® polarimeter sample chamber to measure within ±0.2°C of the USP, EP, JP, or BP specified temperature (normally 20°C or 25°C ±0.5°C)

Rudolph provides a temperature validation cell with every polarimeter TempTrol™ system. The temperature validation cell along with optional NIST traceable thermometer is designed to validate the temperature control performance of the polarimeter and cell to ±0.2°C.


cGMP/GLP Printing

Measurement reports can be saved as an Excel or PDF file and edited quickly and easily. You can import logos and print your company’s customized “C of A” directly directly from the Autopol V Polarimeter.


Intuitive Windows® Embedded Based Interface

  • 32 gigabytes of internal memory allow almost unlimited capacity for saving measurement data. The AUTOPOL® V is network ready and data may also be saved directly to your server or to any directory desired.
  • Internet access is possible directly from the AUTOPOL® V’s touch screen. This feature allows real time contact with Rudolph Research Analytical’s Service and Technical Support Team who can access your instrument remotely to assist in Window navigation, method setup and troubleshooting.
  • Windows® based navigation architecture is so intuitive that most operators will never read the manual. But should you wish to reference the manual, it is stored right on the AUTOPOL® V’s internal memory.
  • Three USB ports allow quick and easy connection to a mouse, keyboard, printer, bar code scanner, or memory stick. One USB port is located on the front of the unit and two USB ports are located on the back of the unit.

Flexible Method Management

Install your own measurement methods for immediate selection of the correct method to match your most common tests. Setting up your own custom methods is as simple as filling out a few screens like the one shown to the right.


Full 21CFR Part 11 Instrument Level Compliance

The AUTOPOL® VI’s 21CFR Part 11 software module is easily enabled through the user friendly touch screen. This module gives you full compliance with:

  • Electronic signature
  • Access levels
  • Internal write protected storage
  • Unique passwords
  • Write protected documents sent directly to server
  • Audit trail


Polarimeter Sample Chamber and Cell – Acid Resistance

The AUTOPOL® V polarimeter is available with Rudolph’s Hastelloy™ upgrade option. This option includes a Hastelloy™ cell and Silco Steel™ cell chamber for increased resistance to acids like 6 Molar HCl.


Specifications

Measuring Mode Optical Rotation Specific Rotation Specific Rotation Plus Concentration User Defined Scale Sugar Degrees °Z(ISS)
Measuring Scale Degrees Arc, % Concentration
Measuring Range ± 89.9° Arc Optical Rotation ± 999.99° Arc Specific Rotation 0-99.9% Concentration
Resolution 0.001° Arc Optical Rotation 0.001% Concentration 0.001 Specific Rotation
Reproducibility 0.002° Arc
Standard Model Accuracy 0.002° up to 1°, 0.2% up to 5°, 0.01° above 5°
AP Model Specs Accuracy (546nm and 589nm): ±0.002° Arc over ±89.9° Arc Accuracy for other wavelengths is the same as the standard model Selectable Resolution 0.01°, 0.001°, 0.0001° Arc Optical Rotation
Prism Glan Thomson calcite quartz
Optical Wavelengths 365nm, 405nm, 436nm, 546nm, 589nm, 633nm (other wavelengths available)
Wavelength Selection Touchscreen Selectable: 6 standard
TempTrol™ Range Automatic Electronic Heating & Cooling 15°-35°C (Standard) ±0.2° C (Standard)
TempTrol™ Accuracy ±0.2°C
Temp. Probe Range 10°-100°C
Temp. Probe Accuracy ±0.1°C
Acid Resistance Hastelloy™ measurement cell and Silco Steel™ sample chamber (optional)
Measurement Time 4°/sec slewing rate & 5 sec nominal settling time
Light Source Tungsten-halogen 6V, 20W, avg. 2,000 hr life
Sample Chamber Accepts sample tubes up to 200mm
Data Storage 32 GB Non-removable Compact Flast
Communication Interface 3 - USB Ports 2 - RS232 Ports Ethernet Port for Network Connection
Calibration Automatic calibration by push-button
Operating System Windows® Embedded
Display 8 inch colour LCD with LED backlight providing 800 x 600 resolution with 400 nits of luminance
User Interface Touchscreen
Automatic Sensitivity Control Measures samples with transmittance as low as 0.01 % (up to O.D. 4.0)
Input Power 100-240 VAC, 50/60 Hz
Operating Dimensions 30"W x 17"H x 10.5"D, 762mm W x 432mm H x 267mm D
Shipping Dimensions 30"W x 11.5"H x 17"D, 762mm W x 431.8mm H x 279.4mm D
Operating Weight 85 lbs (39 kg)
Shipping Weight 120 lbs. (54kg)